Industrial fluid power & energy systems kernels
Hydraulic (pressurized-liquid) power transmission, pneumatic (compressed-air) power transmission, and grid-scale AC power engineering — three independent kernel modules, none of which overlap with the
Three independent modules for moving power around a plant or a grid without a shaft connecting the source to the load. hydraulics is force and motion carried by a pressurized, effectively incompressible liquid — Pascal's law, cylinder sizing, pump displacement, accumulator sizing. pneumatics is the same job done with a compressible gas instead — Boyle's law, orifice and pipe flow, compressor sizing, air receivers and dryers. power_systems is a level up from both: it is not fluid power at all, but AC/DC electrical power engineering at the scale of a transformer, a feeder line, or a whole grid's demand curve — three-phase power, transformer ratios, line loss, power factor, and load factor. All thirty-six functions across the three modules take and return plain Float64 scalars, so each one is a single checkable formula with no struct or status-code layer in between.
from algenta import MojoRuntime
runtime = MojoRuntime(mode="local")
# Pascal's law: a 100 kPa pressure over a 0.01 m^2 piston
runtime.execute("hydraulics", "pascals_law_force", [100000.0, 0.01])["result"]
# 1000.0 -- F = P * A, in newtons
# Boyle's law: 10 L of gas at 200 kPa, compressed to 400 kPa
runtime.execute("pneumatics", "ideal_gas_volume", [200.0, 10.0, 400.0])["result"]
# 5.0 -- V2 = P1*V1/P2, isothermal
# 230 V, 10 A, power factor 0.8
runtime.execute("power_systems", "active_power", [230.0, 10.0, 0.8])["result"]
# 1840.0 -- P = V*I*PFThe modules
hydraulics
Pascal's-law force and pressure, cylinder sizing and velocity, pump displacement, hydraulic power, a simplified pressure-loss term, gas-charged accumulator sizing, relief-valve flow, oil compressibility, and cylinder bore from a target force.
pneumatics
Boyle's-law gas expansion, orifice and Darcy-Weisbach pipe flow, isothermal compressor power, cylinder force and speed for pneumatic actuators, air-receiver sizing, free-air-delivery normalization, specific power, and a simplified pressure-dew-point estimate.
power_systems
AC/DC active, reactive, and apparent power; power factor; three-phase power; transformer turns ratio and secondary voltage; line loss and voltage drop; power efficiency; capacitor reactive power; and demand load factor.
hydraulics: Pascal's law, cylinders, pumps, and accumulators
pascals_law_force(pressure, area)
F = P * A.
pascals_law_pressure(force, area)
P = F / A.
hydraulic_advantage(area_output, area_input)
MA = A_out / A_in — the force multiplication of a two-piston hydraulic jack.
flow_rate_cylinder(area, velocity)
Q = A * v.
cylinder_velocity(flow_rate, area)
v = Q / A — the inverse of flow_rate_cylinder.
pump_displacement(flow_rate, rpm)
D = Q / RPM, displacement per revolution.
hydraulic_power(pressure, flow_rate)
P = pressure * Q, watts when pressure is in Pa and flow in m³/s.
system_pressure_loss(flow_rate, resistance)
ΔP = Q² * R — the docstring itself calls this "simplified": a single lumped-resistance term standing in for the sum of a real circuit's line, fitting, and valve losses.
accumulator_volume(gas_precharge, min_pressure, max_pressure)
V = Vp * (Pmax/Pmin - 1) — see below.
relief_valve_flow(pressure, cracking_pressure, gain)
(P - Pc) * gain once P exceeds the cracking pressure, else 0.0; at P == Pc exactly it also returns 0.0 (the comparison is strict >, not >=).
oil_compressibility(volume, pressure_change, bulk_modulus)
ΔV = V * ΔP / B — how much a trapped volume of hydraulic oil shrinks under a pressure rise, given the fluid's bulk modulus.
cylinder_bore_from_force(force, pressure)
d = sqrt(4F / (π·P)) — the bore diameter needed to produce a target force at a given pressure.
None of these twelve functions guard a zero or negative denominator. hydraulics.mojo has exactly one conditional in the whole file — the strict > in relief_valve_flow — and it exists to gate the valve, not to protect a division. pascals_law_pressure(F, 0.0), hydraulic_advantage(a, 0.0), cylinder_velocity(q, 0.0), and pump_displacement(q, 0.0) all divide by their second argument with nothing stopping a 0.0 from producing inf or -inf, and cylinder_bore_from_force takes sqrt of 4*force/(π*pressure) with no check that the argument under the root is non-negative — a negative pressure produces NaN rather than a refused call. This is a real, checkable contrast with pneumatics.mojo below, which guards every one of its divisions.
accumulator_volume's formula puts the wrong pressure on the bottom. With only gas_precharge, min_pressure, and max_pressure as arguments and no separate precharge-pressure input, the only physically consistent reading is that gas_precharge (Vp in the docstring) is the gas volume at the state where the accumulator sits at min_pressure — the ordinary simplifying assumption for a two-pressure sizing problem. Boyle's law (P·V = const, the same relation pneumatics.ideal_gas_volume implements directly) then gives the usable oil volume swept between min_pressure and max_pressure as Vp * (1 - min_pressure/max_pressure), not Vp * (max_pressure/min_pressure - 1) as implemented. The two agree only when min_pressure == max_pressure (both 0.0); everywhere else the implemented formula returns more oil than Boyle's law allows, and the gap grows with the pressure ratio. Concretely, for accumulator_volume(10.0, 100.0, 200.0) (the module's own test case), Boyle's law gives 10.0 * (1 - 100/200) = 5.0, while the implemented formula returns 10.0 * (200/100 - 1) = 10.0 — exactly double, because 200/100 and 1 - 100/200 are reciprocal-shaped ratios that only coincide when the pressure ratio is 1. A caller sizing a real accumulator's precharge off this function's return would size it for half the delivered oil volume the number promises.
pneumatics: Boyle's law, orifices, compressors, and air treatment
ideal_gas_volume(pressure1, volume1, pressure2)
Boyle's law: V2 = P1*V1/P2; 0.0 if pressure2 is within 1e-30 of zero.
flow_rate_orifice(cd, area, pressure_drop, density)
Q = Cd * A * sqrt(2*ΔP/ρ); 0.0 if density is near zero or the term under the root would be negative.
compressor_power(flow_rate, p1, p2, efficiency)
Isothermal compression power, P = Q*P1*ln(P2/P1)/eff; 0.0 if efficiency or p1 is near zero, or the pressure ratio is non-positive.
pressure_drop_pipe(f, length, diameter, density, velocity)
Darcy-Weisbach: ΔP = f*(L/D)*ρ*v²/2; 0.0 if diameter is near zero.
air_consumption(bore_diameter, stroke, pressure, cycles_per_min)
Double-acting-cylinder air draw: π/4*d²*stroke*2*(pressure/101.325)*cycles, i.e. bore-swept volume per cycle times the ratio of working pressure to standard atmospheric pressure (101.325 kPa), times cycles per minute.
cylinder_force(bore_area, pressure)
F = A * P, newtons.
bore_area(diameter)
A = π*d²/4.
piston_speed(stroke, cycles_per_min)
v = 2*stroke*cycles/60, m/s (the 2 counts both strokes of a double-acting cycle).
receiver_volume(flow_rate, run_time, p_max, p_min)
V = Q*t/(Pmax - Pmin); 0.0 if the pressure band is within 1e-30 of zero.
free_air_delivery(measured_flow, measured_pressure, atm_pressure)
FAD = flow * measured_pressure / atm_pressure; 0.0 if atm_pressure is near zero.
specific_power(power_kw, fad)
SP = power/FAD, kW per m³/min of free air delivered; 0.0 if fad is near zero.
dew_point_pressure(atm_dew_point, pressure_ratio)
Its own docstring calls this "simplified": DP ≈ atm_dp + 10*ln(ratio); returns atm_dew_point unchanged if pressure_ratio <= 0.0.
Every division in this module is guarded, and consistently — eight of the twelve functions above check their denominator against fabs(x) < 1e-30 (or an equivalent non-positive check on a ratio or a square-root argument) before dividing, returning 0.0 rather than inf/NaN. That is a deliberate, file-wide pattern, not incidental: hydraulics.mojo has no equivalent guard anywhere, and power_systems.mojo (below) guards with an exact == 0.0 rather than an epsilon band.
air_consumption's docstring calls its pressure argument "gauge," but the module treats it as absolute. The parameter comment reads "Working gauge pressure (kPa abs)" — gauge and absolute in the same phrase — and the arithmetic and the module's own test settle it: air_consumption(0.1, 0.5, 101.325, 1.0) (pressure passed as exactly one standard atmosphere) is verified against π/4*0.01*0.5*2*(101.325/101.325)*1.0 ≈ 0.007854, i.e. a pressure ratio of exactly 1.0 at atmospheric pressure — the ratio a gauge reading of 101.325 (which would mean roughly two atmospheres absolute) would not produce. The argument is an absolute pressure in kPa; the word "gauge" in the docstring is a naming error, not a unit convention a caller should follow.
A worked compressor-sizing chain. A double-acting cylinder with a 100 mm bore (bore_area(0.1) = 0.0078540 m²) driven at 600 kPa produces cylinder_force(0.0078540, 600000.0) ≈ 4712.39 N per stroke. Cycling at 60 cycles/min with a 0.3 m stroke, air_consumption(0.1, 0.3, 600.0, 60.0) = 0.0078540*0.3*2*(600/101.325)*60 ≈ 1.6743 m³/min of free air at working pressure. Sizing a receiver to ride out a 5-second compressor-off period between a 700 kPa and a 650 kPa band, receiver_volume(1.6743, 5.0/60.0, 700.0, 650.0) ≈ 0.00279 m³ (about 2.8 liters) — the same shape of chained call as any other module in this corpus, each function's output feeding the next's input.
power_systems: AC power, transformers, and grid-scale losses
active_power(voltage, current, power_factor)
P = V*I*PF, real (working) power.
reactive_power(voltage, current, power_factor)
Q = V*I*sin(φ), computed as sin(φ) = sqrt(1 - PF²) — see below for what happens outside PF ∈ [-1, 1].
apparent_power(voltage, current)
S = V*I, the vector sum of active and reactive power.
power_factor_from_pq(p, s)
PF = P/S; 0.0 if s == 0.0 exactly.
three_phase_power(v_line, i_line, pf)
P = √3 * V*I*PF, balanced three-phase active power.
transformer_turns_ratio(v_primary, v_secondary)
a = Vp/Vs; 0.0 if v_secondary == 0.0 exactly.
transformer_secondary_voltage(v_primary, turns_ratio)
Vs = Vp/a; 0.0 if turns_ratio == 0.0 exactly.
line_loss(current, resistance)
P_loss = I²*R.
voltage_drop(current, resistance, length)
V_drop = 2*I*R*L — the 2 accounts for the round-trip conductor (out and back), so resistance is a per-unit-length figure.
power_efficiency(output_power, input_power)
η = Pout/Pin; 0.0 if input_power == 0.0 exactly.
capacitor_reactive_power(voltage, capacitance, frequency)
Qc = V² * 2πfC.
load_factor(avg_demand, peak_demand)
LF = avg/peak; 0.0 if peak_demand == 0.0 exactly.
Every guard here checks for exact == 0.0, not a near-zero band. Unlike pneumatics.mojo's fabs(x) < 1e-30 epsilon guards, the five division guards in this module (power_factor_from_pq, both transformer functions, power_efficiency, load_factor) only trip on a denominator that is precisely 0.0. A denominator of 1e-300 — non-zero in floating point, but not meaningfully different from zero for any real grid measurement — passes every guard here and produces a finite but enormous result rather than the module's own 0.0 sentinel.
reactive_power has no domain guard on power_factor, and it is reachable with an ordinary-looking input. sin(φ) is computed as sqrt(1 - PF²), which is only real for PF ∈ [-1, 1]. A power factor is dimensionless and by convention stays in that range, but nothing in the function stops a caller from passing one outside it — a miscomputed power_factor_from_pq result greater than 1.0 (possible if a caller mixes up which value is P and which is S) flows straight into reactive_power and produces 1.0 - PF² negative, so sqrt returns NaN with no guard to catch it, unlike every division in this same module.
A worked chain: active_power(230.0, 10.0, 0.8) = 1840.0 W and apparent_power(230.0, 10.0) = 2300.0 VA give back power_factor_from_pq(1840.0, 2300.0) = 0.8 exactly — the three functions round-trip. reactive_power(230.0, 10.0, 0.8), with sin(φ) = sqrt(1 - 0.64) = 0.6, is 1380.0 VAR, and 1840² + 1380² = 2300² to floating-point precision — active and reactive power really do form the two legs of the right triangle apparent power is the hypotenuse of. For a 400 V line at 50 A and PF = 0.9, three_phase_power(400.0, 50.0, 0.9) = √3 * 400 * 50 * 0.9 ≈ 31176.91 W.
A distinct sibling module this page does not cover: electrical
The runtime library contract also defines a fourteen-function module named electrical — but reading its actual functions (ohms_law_v/_i/_r, series_resistance, parallel_resistance, voltage_divider, rc_time_constant, rc_voltage, rlc_resonance, inductive_reactance, capacitive_reactance, impedance_magnitude, power_dc, power_factor) shows it is component-level DC/AC circuit theory — Ohm's law, resistor networks, RC/RLC transient and resonant behavior, impedance — not grid-scale power engineering. It shares no functions and no formulas with power_systems: the two modules answer different questions at different scales, one about a single circuit element, the other about a transformer, a feeder, or a whole demand curve. electrical is not documented on this page or anywhere else in gitbook/ as of this writing — grepping the corpus for it turns up only the runtime library catalog's function count and an unrelated mention of a wave-test file's title — so it remains a real gap, but a separate one from the three modules covered here.
Verification
mojo/tests/libs/test_hydraulics.mojo, test_pneumatics.mojo, and test_power_systems.mojo are the auto-generated coverage smoke tests for these three modules: each calls every function once with literal 0.5 arguments (0.5, 0.5, 0.5 for accumulator-style three-argument functions) and checks only that the result is finite. They do not pin any specific numeric output.
Real, hand-verified numeric suites exist for all three modules in tests/mojo/: test_wave95.mojo ("Wave 95: semiconductors, viticulture, hydraulics") checks hydraulics against independently worked values, including two explicit round-trips (pascals_law_force → pascals_law_pressure back to the original pressure, and cylinder_bore_from_force fed back through π*d²/4*pressure to recover the original force); test_wave94.mojo checks all twelve pneumatics functions against hand-computed values (22 assertions); and test_wave66.mojo ("Wave 66 — Robotics, Psychometrics, Power Systems") checks all twelve power_systems functions, including the active/reactive/apparent-power right-triangle relationship and a transformer round-trip. Every worked number in this page came from one of those three files or was independently recomputed in plain Python against the formula in the corresponding mojo/engine/*.mojo source, including the accumulator_volume discrepancy above, which was checked both symbolically and against the module's own 10.0/100.0/200.0 test case.
Next: see Thermal, cryogenic, and energy kernels for the battery and renewable-generation physics that sits on the other side of power_systems' grid, or browse the Runtime library catalog for every module and function.